STALLION TECHNOLOGIES, INC. EC 8/64-AT Card Type Serial Processor 80186 Processor Speed 25MHz Chipset Cirrus Logic CL-CD1400 (on expansion box) Maximum Onboard Memory 512KB RAM I/O Options Serial ports (64) Data Bus 16-bit ISA Card Size Full height, half length [Image] CONNECTIONS Function Label Serial ports via DB-50 connector CN1 Note:Standard RS-232 or RS-422 serial ports via DB-25 or RJ-45 connectors are provided on external expansion boxes. USER CONFIGURABLE SETTINGS Setting Label Position » Factory configured - do not alter SW1/8 Off BASE I/O ADDRESS SELECTIONS Setting SW1/1 SW1/2 SW1/3 SW1/4 SW1/5 SW1/6 SW1/7 000h On On On On On On On 004h Off On On On On On On 008h On Off On On On On On 00Ch Off Off On On On On On 010h On On Off On On On On » 2A0h On On On Off On Off On 3ECh Off Off On Off Off Off Off 3F0h On On Off Off Off Off Off 3F4h Off On Off Off Off Off Off 3F8h On Off Off Off Off Off Off 3FCh Off Off Off Off Off Off Off Note: A total of 128 base address settings are available. The switches are a binary representation of the decimal memory addresses. SW1/7 is the Most Significant Bit and switch SW1/1 is the Least Significant Bit. The switches have the following decimal values: SW1/7=256, SW1/6=128, SW1/5=64, SW1/4=32, SW1/3=16, SW1/2=8, SW1/1=4. Turn off the switches and add the values of the switches that are off to obtain the correct memory address. (Off=1, On=0)